Accurate and reliable conductivity measurement made easy

The SIGMATEST 2.070 is a portable eddy current instrument which measures the electrical conductivity of non-ferromagnetic metals based on the complex impedance of the measuring probe.

It determines physical and technical material properties. Typical applications include controlling the quality of manufactured products, testing material combinations, and sorting metals, alloys, and scrap metal. The unit is also used for the maintenance of aircrafts, determining heat damage, and in-process controls during production and processing in the metallurgy sector. It features five different excitation frequencies and an extremely high measuring accuracy. The unit retains this high level of accuracy even at a high frequency of 960 kHz, making it possible to measure very thin workpieces with great precision. The measuring instrument is able to automatically standardize the measured value of the electrical conductivity to 20°C due to an integrated temperature compensation. The measurement quality meets Boeings (BAC 5651) and Airbus standards.

Operating Modes
The SIGMATEST 2.070 is capable of operating in either Touch- or Continuous mode. Use Continuous mode to scan surfaces and display the measurement values in a time chart or Touch to measure single values. Use the recording function to save all measurements.

Correction Factor
Variations in the material geometry can produce a measurement error. One example is measurement on test pieces with curved (either concave or convex) surfaces. If the conductivity value of the test piece is known, the error caused by the curvature of the surface can be corrected by using a correction factor. The measured value is multiplied by the correction factor and the corrected value is displayed on the LCD.

The SIGMATEST 2.070 "remembers"
The SIGMATEST 2.070 now automatically receives the correct calibration curve from the probe. This feature is especially useful when using both 5 mm, 8 mm and 14 mm probes with the same instrument.

Temperature compensation
The SIGMATEST 2.070 compensates for temperature related electrical conductivity variations. A default temperature coefficient is installed in each instrument. In addition, the user can define a specific temperature coefficient to optimize the results for specific applications. Temperature measurement is performed using either the temperature sensor which is integrated into the probe or by connecting an external temperature sensor. An external temperature sensor is recommended when the temperature of the test piece differs from the probe temperature.

 

 YouTube Playlist

Your advantages at a glance

  • Five measuring frequencies 60, 120, 240, 480, 960 kHz
    The high frequency of 960 kHz allows accurate electrical conductivity measurement on very thin pieces
  • 50 measurements per second
  • Easy operation in either touch or continous mode
  • Internal and external temperature compensation
  • Measurement possible up to 0.75 mm distance from the test item
  • Measurement range from 0.5 to 65 MS/m (1-112 % IACS)
  • Remote control by an external PC is possible via Ethernet standard RJ45. The interface allows complete control over the instrument and an integration in automated systems
  • SD-card slot for saving nearly an unlimited amount of test data
  • Probe characteristics are directly saved on the probe and automatically read by the device
  • Multilanguage operating system
  • Robust device design for operation on site

Technical Data

Measuring range:0.5 to 65 MS/m or 1 to 112 % IACS
Absolute accuracy:+/- 0.7 % of measured value @60 kHz, 14 mm probe
Resolution:+/- 0.1 % of measured value
Automatic distance compensation:Up to 750 μm (0.03 inch)
Operating frequencies:60 / 120 / 240 / 480 / 960 kHz
LCD display:480 x 640 pixel
Power supply:5V DC / 3000 mA
Operating time per set of batteries:4 h
Operating voltage:Power supply and battery charger adaptable to the operating voltage in any country
Interfaces:10 pin LEMO connector, SD card slot, Ethernet RJ45 100 Mbit/s
Temperature range:0 °C to +40 °C (32 °F to 104 °F)
Humidity:5 % to 85 %
Dimension:211 x 102 x 40 mm
Weight:0.62 kg
Standards:DIN 50994, ASTM E 1004, DIN EN 2004-1

Widths of the probe head

5 mm, 8 mm, 14 mm

 

For more information about our calibration standards - read our blog post:
The different types of calibration standards for measuring electrical conductivity

This website uses cookies

We use cookies to personalize content and advertisements, to be able to offer functions for social media and to analyze access to our website. We also share information about your use of our website with our social media, advertising and analytics partners. Our partners may combine this information with other data that you have provided to them or that they have collected as part of your use of the services.

Our cookies have changed, so you will need to give your consent again.

Your previous consent to our cookies has expired, so you will need to consent again.

Necessary cookies help to make the website usable for the user. They store basic information, such as a login to the website or the consent to the individual cookies.

Name Provider Purpose Duration Type
YSC YouTube

YouTube Video

Sitzung Cookie
CONSENT YouTube

YouTube Video

2 Jahre Cookie
VISITOR_INFO1_LIVE YouTube

YouTube Video

6 Monate Cookie
__hs_opt_out HubSpot notwendig

This cookie is used by HubSpot to ensure that a user after an opt-out does not have to ask for consent again.

13 months Cookie
__hs_do_not_track HubSpot notwendig

This cookie is used by HubSpot to disable the tracking of a user.

13 months Cookie
__hs_initial_opt_in HubSpot notwendig

This cookie is used by HubSpot to store the consent to tracking.

7 days Cookie
hs_ab_test HubSpot notwendig

This cookie is used by HubSpot to always assign a user to the same group during A/B tests.

Session Cookie
*_key HubSpot notwendig

This cookie is used by HubSpot to prevent a user from having to log in multiple times for the same content.

14 days Cookie
hs-messages-is-open HubSpot notwendig

This cookie is used by HubSpot to save chat widget settings.

30 minutes Cookie
hs-messages-hide-welcome-message HubSpot notwendig

This cookie is used by HubSpot to ensure that the welcome message of the chat is displayed once a day.

1 day Cookie
__hsmem HubSpot notwendig

This cookie is used by HubSpot to store the login process of a user.

1 year Cookie
hs-membership-csrf HubSpot notwendig

This cookie is used by HubSpot to prevent a login process from being corrupted.

Session Cookie
hs_langswitcher_choice HubSpot notwendig

This cookie is used by HubSpot to store the language selected by the user.

2 years Cookie
__cfduid HubSpot notwendig

This cookie is used by HubSpot to securely transfer data via CDN / Cloudfare.

Session / 30 days Cookie
__cfruid HubSpot notwendig

This cookie is used by HubSpot to securely transfer data via CDN / Cloudfare.

Session Cookie
gits_cookie_accepted_* digiwerk GmbH

Saves the cookie banner selection.

unlimited LocalStorage
fe_typo_user TYPO3

Wird vom CMS-System TYPO3 benötigt, um Benutzer am Frontend anmelden zu können.

1 Jahr Cookie
DataTables_* TYPO3

Is stored by the CMS system TYPO3 vebSaves user settings for displaying data in the backend.

unlimited LocalStorage
t3-tabs-* TYPO3

Saves user settings for displaying data in the backend.

unlimited LocalStorage
be_typo_user TYPO3

Required by the CMS system TYPO3 to allow users to log on to the backend.

1 year LocalStorage
PHPSESSID TYPO3

Required by the CMS system TYPO3 to allow users to log on to the backend.

1 year Cookie

Marketing cookies help to recognize visitors to websites. This enables, among other things, to show them more accurate advertisements and search results.

Name Provider Purpose Duration Type
__hstc HubSpot

This cookie is used by HubSpot to register a unique ID that can be assigned to statistical data of the user.

13 months Cookie
hubspotutk HubSpot

This cookie is used by HubSpot to register a unique ID that can be assigned to statistical data of the user.

13 months Cookie
__hssc HubSpot

This cookie is used by HubSpot to detect the session of a user.

30 minutes Cookie
__hssrc HubSpot

This cookie is used by HubSpot to detect the session of a user.

Session Cookie

Statistical cookies help to understand how visitors interact with the site by collecting and reporting information anonymously.

Name Provider Purpose Duration Type
_pk_id.*.* Matomo

This cookie is used by Matomo to store some details about the user, such as the unique visitor ID.

13 months Cookie
_pk_ses.*.* Matomo

This cookie is used by Matomo, for short-lived cookies, which are used for temporary storage of data for the visit.

30 minutes Cookie
_pk_testcookie..undefined Matomo

This cookie is used by Matomo to check whether the visitor’s browser supports cookies

Session Cookie

Cookies are small text files that are used by websites to make the user experience more efficient.According to the law, we can store cookies on your device if they are absolutely necessary for the operation of this site. We need your permission for all other types of cookies.This site uses different types of cookies. Some cookies are placed by third parties that appear on our pages.