Eddy current testing for safe components
We aim to produce safe component for the automotive sector. This is why we use fixed and rotating differential eddy-current probes with high test sensitivity for component crack testing. A comprehensive selection of different standard sensors is available to suit various test tasks. FOERSTER designs and manufactures individual special sensors tailored to meet your requirements for any test task requiring special solutions.
Your advantages at a glance
- Individual probes for permanent installation in a testing station
- Scanning of a scanning track which is produced either by moving the test piece or by moving the probe
- Different designs: round, flat, angled
- Individually adapted special probes
- Diverse rotating heads with adapted rotating probes
Technical Data
PROBES | |
Clearance compensation: | optional |
Width of coverage: | 0,8 mm to 5 mm |
Frequency range: | up to 1 MHz and10 MHz |
Test sensitivity: | High |
Electrical and mechanical stability: | High |
ROTATING HEAD | |
Rotating probe speed: | nmax=15,000 min-1 |
Frequency range: | 100 kHz -1 MHz |